SAMx update (last edited: 3-Jul-08) =================================== The updated files are to be installed over the version which was distributed on SAMx CDROM 8.8 to 8.12 XMAS Updated files (3-Jul-08) --------------------------------- Files updated: xm_pea.dll.......(version 16.9) xm_mspec.dll.....(version 16.9) xmas_st.exe......(version 14.2) ShowPk.exe.......(version 8.4) xm_comp.dll......(version 12.23) xm_std.exe.......(version 7.5) xm_search.dll....(version 1.2) xm_quali.exe.....(version 7.1) xm_lib.dll.......(version 5.3) xmgrf.ocx........(version 1.2) xm_micro.dll.....(version 5.26) xm_acq.exe.......(version 8.19) xm_xl.dll........(version 2.0) xm_picox.dll.....(version 2.6) xm_lsacq.exe.....(version 4.8) xm_import.dll....(version 2.60) xm_sinus.dll.....(version 3.3) Description: Remove temporary test on spectrometer movement on Mash ( fix in 16.9) The Mash stage didn't work anymore (fix with 16.8) Add a 20msec delay after the status command Change scheme when reading the counters in the Mash system Add a delay before starting the counters in Standalone (Pk-Bg) Correct crystal switch for Mash Improve peak search Load Slit posiiton twice on Microspec at the end of peak search Fix a bug when calculating off-line analysis in XMAS of EDS data only Add a "?" button in the WDS Acquisition (Standard) to search for possible Spectrometer position Correct crystal change in Mash configuration Correct crash of Spectrum Processing in the label function Change background of cursor in Spectrum Processing Correct a few items for Microspec Display Stage scan as position if one axis scan otherwise by point number Correct random crash of live spectrum display Reduce timeout for Mash driver Correct Stage Line scan, use actual stage position to display the spectrum Correct setting of current when multiconditions are used Extend the number of elements in the standard from 25 to 28 Correct import of SX100 files The statistic calculation is now working properly. The peak search uses the maximum if too few channels are above the noise Standalone now has a way to measure Peak to Background Standalone support 5 stage axes Hard code the LIF crystal for Microspec in LineScan Correct communication with PHA for Mash Add sinus & XL drivers Forcing the XTal change of the existing Xtal in standalone only in Mash The Mash driver was compiled in Debug mode and didn't access the hardware Correct wrong call to Jeol External DLL Correct statistic calculation, the range was sometime wrong Force Xtal even if the Xtal is already in place Mash. IDFix Updated files (04-Mar-08) --------------------------------- Files updated: xm_qtx.dll.....(version 23.7) xm_lib.dll.....(version 5.2) xm_numerix.dll.(version 14.3) IDFix.exe......(version 8.2) Description: Correct display of individual fit Correct EMSA import, don't save the spectrum offset Support different NumeriX clock frequency (TimeFactor) The error display is not the Chi2 of the deconvolution Speed up the communication with the NumeriX box Correct display of deconvolute spectrum of identify elements Add a few downloaded files to the NumeriX box Correct background calculation when actual calculated concentrations is used HiMax Updated files (03-Mar-08) --------------------------------- Files updated: HiMax.exe.......(version 9.18) xm_batch.exe....(version 6.02) Description: Correct HiMax acquisition in Batch mode MaxView Updated files (1-Feb-08) --------------------------------- Files updated: MaxView.exe.....(version 8.10) Mv_data.dll.....(version 6.0) xm_xlacq.exe......(version 3.1) Description: Correct the Particle Analysis program when use with quantitative images. Correct regular Xray map when L or M lines were used Correct the crash of combination of images Remove error message when starting an XL acquisition The magnification was not read correctly